Animal Health
R-Biopharm Australia’s Animal Health diagnostics portfolio provides advanced molecular diagnostic solutions for the detection of pathogens affecting companion animals and livestock. Using multiplex PCR technology, our veterinary diagnostic panels enable laboratories to identify multiple bacterial, viral, parasitic and fungal targets from a single sample, supporting accurate diagnosis, disease monitoring and improved animal health management.
Comprehensive Veterinary Pathogen Detection
Animal diseases can be caused by a diverse range of pathogens, many of which share similar clinical signs and require targeted testing approaches for accurate identification. R-Biopharm Australia’s multiplex PCR solutions provide comprehensive pathogen detection across a range of veterinary applications, allowing laboratories to assess multiple relevant targets simultaneously from a single sample.
From companion animal health to livestock disease management, our diagnostic panels support veterinary laboratories with reliable molecular insights that assist disease investigation, surveillance programs and informed health management decisions.

Animal Health Product Portfolio
Small Animals
Panels for the most common pathogenic bacteria, viruses, parasites, and fungi for efficient veterinary screening in domestic animals, such as felines and canines.
Bacteria
- Bartonella spp.
- Borrelia spp.
- Leptospira interrogans
- Streptococcus spp.
- Staphylococcus spp.
Fungi
- Cryptococcus gattii
- Cryptococcus laurentii
- Cryptococcus neoformans
Parasites
- Angiostrongylus spp.
- Neospora caninum
- Toxoplasma gondii
Viruses
- Canine Distemper Virus
- Canine Herpesvirus 1
- Feline Coronavirus
- Feline Leukaemia Virus
- Feline Immunodeficiency Virus
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28163S | RIDA®Plex Small Animal Neurological 16 well Step 1 | 12 x 8-well Strips | 96 |
| 28163P | RIDA®Plex Small Animal Neurological 16 well Step 2 | 12 x 384-well Plates | 288 |
| 40331 | RIDA®Plex L RNA Cassette | 10 Cassettes | – |
| 91260 | RIDA®Plex Positive Control Veterinary Panels B | 10 x 2mL Tubes | – |
Bacteria
- Mycoplasma haemofelis / haemominicans complex
- Mycoplasma haemominutum
- Mycoplasma haematoparvum
- Mycoplasma turicensis
- Anaplasma platys
- Bartonella spp.
- Ehrlichia canis
Parasites
- Babesia gibsoni
- Babesia vogeli
- Hepatozoon canis
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28201S | RIDA®Plex Small Animal Anaemia 16 well Step 1 | 12 x 8-well Strips | 96 |
| 28201P | RIDA®Plex Small Animal Anaemia 16 well Step 2 | 12 x 384-well Plates | 288 |
| 40231 | RIDA®Plex L DNA Cassette | 10 Cassettes | – |
| 91330 | RIDA®Plex Positive Control Veterinary Panels A | 10 x 2mL Tubes | – |
Bacteria
- Mycoplasma canis
- Mycoplasma cynos
- Mycoplasma felis
- Bordetella bronchiseptica
- Chlamydia felis
Fungi
- Cryptococcus gattii
- Cryptococcus laurentii
- Cryptococcus neoformans
- Aspergillus spp.
- Pneumocystis canis
Parasites
- Toxoplasma gondii
Viruses
- Canine Adenovrus Type 2
- Canine Herpesvirus 1
- Canine Parainfluenza Virus
- Canine Respiratory Coronavirus
- Feline Calcivirus
- Feline Herpesvirus 1
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28202S | RIDA®Plex Small Animal Respiratory 16 well Step 1 | 12 x 8-well Strips | 96 |
| 28202P | RIDA®Plex Small Animal Respiratory 16 well Step 2 | 12 x 384-well Plates | 288 |
| 40331 | RIDA®Plex L RNA Cassette | 10 Cassettes | – |
| 91330 | RIDA®Plex Positive Control Veterinary Panels A | 10 x 2mL Tubes | – |
Bacteria
- Campylobacter coli
- Campylobacter jejuni
- Clostridium perfringens (including enterotoxins CPE and NetF)
- Salmonella spp.
Parasites
- Cryptosporidium canis
- Cryptosporidium felis
- Giardia lamblia
- Neospora caninum
- Toxoplasma gondii
- Trichomonas foetus
Viruses
- Canine Distemper Virus
- Canine Enteric Coronavirus
- Canine Parvovirus
- Feline Coronavirus
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28174S | RIDA®Plex Small Animal Diarrhoea 16 well Step 1 | 12 x 8-well Strips | 96 |
| 28174P | RIDA®Plex Small Animal Diarrhoea 16 well Step 2 | 12 x 384-well Plates | 288-576^ |
| 40331 | RIDA®Plex L RNA Cassette | 10 Cassettes | – |
| 91260 | RIDA®Plex Positive Control Veterinary Panels B | 10 x 2mL Tubes | – |
Livestock
Our avian, bovine and equine disease panels deliver comprehensive, species‑specific detection of key viral and bacterial pathogens, supporting rapid diagnosis, effective surveillance, and informed health and biosecurity management across poultry, cattle and horses.
Bacteria
- Chlamydophila psittaci
Parasites
- Isospora spp.
Viruses
- Avian Bornavirus
- Avian Polyomavirus
- Psittacine Beak and Feather Disease
- Psittacine Herpesvirus
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28123S | RIDA®Plex Avian Diseases 8 well Step 1 | 12 x 8-well Strips | 96 |
| 28123P | RIDA®Plex Avian Diseases 8 well Step 2 | 12 x 384-well Plates | 192 |
| 40341 | RIDA®Plex L RNA Cassette | 10 Cassettes | – |
| 91330 | RIDA®Plex Positive Control Veterinary Panels A | 10 x 2mL Tubes | – |
Bacteria
- Mannheima haemolytica
- Mycoplasma bovis
- Mycoplasma spp.
- Histophilus somni
- Pasteurella multocida
Viruses
- Bovine Coronavirus
- Bovine Herpesvirus 1
- Bovine Parainfluenza Virus 3
- Bovine Respiratory Syncytical Virus
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28149S | RIDA®Plex Bovine Respiratory 12 well Step 1 | 12 x 8-well Strips | 96 |
| 28149P | RIDA®Plex Bovine Respiratory 12 well Step 2 | 12 x 384-well Plates | 288 |
| 40331 | RIDA®Plex L RNA Cassette | 10 Cassettes | – |
Parasites
- Babesia bigemina
- Babesia bovis
- Theileria orientalis (genotypes Buffeli, Chitose, Ikeda and Type 5)
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28171S | RIDA®Plex Theileria 8 well Step 1 | 12 x 8-well Strips | 96 |
| 28171P | RIDA®Plex Theileria 8 well Step 2 | 12 x 384-well Plates | 288 |
| 40241 | RIDA®Plex S DNA Cassette | 10 Cassettes | – |
| 91260 | RIDA®Plex Positive Control Veterinary Panels B | 10 x 2mL Tubes | – |
Bacteria
- Chlamydophila psittaci
- Rhodococcus equi
- Streptococcus equi
- Streptococcus zooepidemicus
Viruses
- Equine Herpesvirus 1
- Equine Herpesvirus 4
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28205S | RIDA®Plex Equine Respiratory 8 well Step 1 | 12 x 8-well Strips | 96 |
| 28205P | RIDA®Plex Equine Respiratory 8 well Step 2 | 12 x 384-well Plates | 288 |
| 40331 | RIDA®Plex S RNA Cassette | 10 Cassettes | – |
Bacteria
- Clostridioides difficile (including toxins A and B)
- Clostridium perfringens (including Beta 2 toxin, enterotoxin CPE and NetF)
- Lawsonia intracellularis
- Salmonella spp.
Parasites
- Cryptosporidium hominis
- Cryptosporidium parvum
- Cryptosporidium spp.
Viruses
- Equine Coronavirus
- Equine Rotavirus
Ordering Information
| Ref | Description | Pack Size | Tests |
|---|---|---|---|
| 28205S | RIDA®Plex Equine Faecal Pathogens 16 well Step 1 | 12 x 8-well Strips | 96 |
| 28205P | RIDA®Plex Equine Faecal Pathogens 16 well Step 2 | 12 x 384-well Plates | 288 |
| 40331 | RIDA®Plex L RNA Cassette | 10 Cassettes | – |
Comprehensive Animal Health Diagnostic Solutions
Our animal health diagnostic portfolio supports veterinary laboratories with advanced molecular solutions for detecting bacterial, viral, parasitic and fungal pathogens across companion animals and livestock. Combining multiplex PCR technology with comprehensive target coverage, our solutions provide reliable insights for disease detection, surveillance and animal health management. Backed by trusted global manufacturers and supported by local expertise, R-Biopharm Australia enables laboratories across Australia to perform veterinary diagnostics with confidence.
A Deep Dive Into Multiplex Tandem PCR
Explore Our Technology
Our animal health diagnostic solutions are supported by advanced molecular testing platforms designed to deliver reliable and efficient pathogen detection across veterinary applications. Combining automated extraction, multiplex PCR technology and integrated workflows, our solutions enable laboratories to process comprehensive panels while maintaining consistent, high-quality results. From companion animal testing to livestock health monitoring, R-Biopharm Australia’s technologies provide flexible solutions for modern veterinary diagnostics.
RIDA®Plex IVD panels are intended for in vitro diagnostics use by authorised clinical testing laboratories in Australia, New Zealand, Great Britain, and the European Economic Area, and are included on the Australian Register of Therapeutic Goods (ARTG), the MHRA database (REF: 10541) and compliant with the European IVD Directive 98/79/EC. In the USA: For Research Use Only (RUO). For Research Use Only (RUO), not for use In diagnostic procedures. RIDA®Plex RUO panels are for Research Use Only in any jurisdiction.
